Re: Initial setup doesn't connect wtih FC3
- From: Matt Davey <mcdavey mrao cam ac uk>
- To: "The PalmOS< tm> integration pacakge" <gnome-pilot-list gnome org>
- Subject: Re: Initial setup doesn't connect wtih FC3
- Date: Fri, 11 Feb 2005 18:04:39 +0000
On Fri, 2005-02-11 at 16:32, Mark Healey wrote:
> Matt Davey wrote:
> >
> > Have you tried increasing the 'timeout' from 2s to 100s?
> >
> > (there's a bug in pilot-link 0.11.8 that means that the timeouts get
> > interpreted in milliseconds, not seconds, so the default 2ms is a pretty
> > severe timeout. This bug has been fixed, and will appear in 0.12.0).
>
> Just tried it, problem persists.
Oh, forgot the obvious: have you added the USB Vendor/Product ID to the
list of recognised IDs for gnome-pilot? If you're running
gnome-pilot-2.0.12 you need to edit the devices.xml file by hand and
restart gnome-pilot.
The Kyocera Vendor ID is 0x0c88, and the device ID for the
7135 is 0x0021.
Matt
[