[chronojump-docs] minor fix
- From: Xavier Padullés <xpadulles src gnome org>
- To: commits-list gnome org
- Cc:
- Subject: [chronojump-docs] minor fix
- Date: Wed, 9 Oct 2019 13:31:58 +0000 (UTC)
commit 22a70c128871710575e80c037af0841f2c2bfd51
Author: Xavier Padullés <x padulles gmail com>
Date: Wed Oct 9 15:31:06 2019 +0200
minor fix
#chronojump_manual_en.lyx# | 14831 -------------------------------------------
chronojump_manual_en.lyx | 257 +-
chronojump_manual_en.lyx~ | 54 +
3 files changed, 150 insertions(+), 14992 deletions(-)
---
diff --git a/chronojump_manual_en.lyx b/chronojump_manual_en.lyx
index c4ca299..0827383 100644
--- a/chronojump_manual_en.lyx
+++ b/chronojump_manual_en.lyx
@@ -9327,7 +9327,68 @@ All the Chronojump sets can be edited.
\end_layout
\begin_layout Standard
-If you want to change
+If you want to change the athlete or the comment associated to the set click
+ on the load button
+\begin_inset Graphics
+ filename images/ForceSensor/Load-Set-Button.png
+ scale 50
+
+\end_inset
+
+ and in the dialog that will be appear click on Edit.
+\end_layout
+
+\begin_layout Standard
+\begin_inset Float figure
+wide false
+sideways false
+status open
+
+\begin_layout Plain Layout
+
+\end_layout
+
+\begin_layout Plain Layout
+\noindent
+\align center
+\begin_inset Graphics
+ filename images/ForceSensor/Edit-Set_en.png
+ scale 50
+
+\end_inset
+
+
+\begin_inset Caption Standard
+
+\begin_layout Plain Layout
+Edit the athlete or comment
+\end_layout
+
+\end_inset
+
+
+\end_layout
+
+\begin_layout Plain Layout
+
+\end_layout
+
+\end_inset
+
+
+\end_layout
+
+\begin_layout Standard
+If you want to change the test type of a set, la laterality or the signal
+ treatment, load first the set, change the desired parameter and click on
+ recalculate
+\begin_inset Graphics
+ filename images/ForceSensor/Recalculate_en.png
+ scale 50
+
+\end_inset
+
+.
\end_layout
\begin_layout Subsection
@@ -9526,132 +9587,6 @@ The RFD refers to Rate of Force Development.
time.
\end_layout
-\begin_layout Paragraph
-Taring and configuring the force sensor
-\end_layout
-
-\begin_layout Standard
-Due to the analog nature of the force sensor, this must be tared and calibrated.
-\end_layout
-
-\begin_layout Paragraph
-Taring
-\end_layout
-
-\begin_layout Standard
-The taring process consists in indicating at which state the sensor should
- register a force of zero Newtons.
-\end_layout
-
-\begin_layout Standard
-To perform this process put the sensor in a horizontal and stable surface
- and, without supporting any external force apart from the weight.
- Then press the button
-\emph on
-Tare.
-
-\emph default
-Chronojump will register for a few seconds and save the results.
-\end_layout
-
-\begin_layout Standard
-
-\lang spanish
-\begin_inset Float figure
-placement H
-wide false
-sideways false
-status open
-
-\begin_layout Plain Layout
-\noindent
-\align center
-
-\lang spanish
-\begin_inset Graphics
- filename /home/xpadulles/chronojump-docs/images/ForceSensor/Tare.JPG
- lyxscale 25
- scale 10
-
-\end_inset
-
-
-\begin_inset Caption Standard
-
-\begin_layout Plain Layout
-Taring the force sensor
-\end_layout
-
-\end_inset
-
-
-\end_layout
-
-\end_inset
-
-
-\end_layout
-
-\begin_layout Paragraph
-Calibration
-\end_layout
-
-\begin_layout Standard
-The calibration consists in stablishing a lineal relationship between the
- electrical signal of the sensor and the real force.
- This relation could change in function of the sensor, temperature, humidity...
- For this reason it is recommended to calibrate once per session.
- By default Chronojump will use a generic calibration.
-\end_layout
-
-\begin_layout Standard
-To perform the calibration, in Chronojump enter the mass in kilograms of
- an object with a known weight.
- Tie this object to the force sensor and lift it making the sensor to hold
- all the weight.
-\lang spanish
-
-\begin_inset Float figure
-placement H
-wide false
-sideways false
-status open
-
-\begin_layout Plain Layout
-\noindent
-\align center
-
-\lang spanish
-\begin_inset Graphics
- filename /home/xpadulles/chronojump-docs/images/ForceSensor/Calibrate.png
- lyxscale 33
- scale 12.5
-
-\end_inset
-
-
-\begin_inset Caption Standard
-
-\begin_layout Plain Layout
-Force sensor calibration
-\end_layout
-
-\end_inset
-
-
-\end_layout
-
-\end_inset
-
-
-\end_layout
-
-\begin_layout Standard
-The closer the weight is to the force you are going to perform in your tests,
- the more precision you will have with this calibration.
- Once you have the load lifted and stable, click on the calibrate button.
-\end_layout
-
\begin_layout Paragraph
Configuring the maximum isometric force test
\end_layout
@@ -11913,40 +11848,6 @@ Encoder
Encoder analyze tab
\end_layout
-\begin_layout Standard
-\begin_inset Float figure
-placement H
-wide false
-sideways false
-status open
-
-\begin_layout Plain Layout
-\begin_inset Graphics
- filename images/encoder-manual-images/analyze.png
- scale 50
-
-\end_inset
-
-
-\end_layout
-
-\begin_layout Plain Layout
-\begin_inset Caption Standard
-
-\begin_layout Plain Layout
-Analyze tab
-\end_layout
-
-\end_inset
-
-
-\end_layout
-
-\end_inset
-
-
-\end_layout
-
\begin_layout Standard
There are four modes of analysis:
\end_layout
@@ -12544,6 +12445,40 @@ The analysis starts when user click in “Analyse”.
each save button in the lower right corner.
\end_layout
+\begin_layout Standard
+\begin_inset Float figure
+wide false
+sideways false
+status open
+
+\begin_layout Plain Layout
+
+\end_layout
+
+\begin_layout Plain Layout
+\begin_inset Graphics
+ filename images/encoder-manual-images/analysis_table_en.png
+ scale 25
+
+\end_inset
+
+
+\begin_inset Caption Standard
+
+\begin_layout Plain Layout
+Data table
+\end_layout
+
+\end_inset
+
+
+\end_layout
+
+\end_inset
+
+
+\end_layout
+
\begin_layout Chapter
Report and export in jumps and races
\end_layout
diff --git a/chronojump_manual_en.lyx~ b/chronojump_manual_en.lyx~
index e802623..c4ca299 100644
--- a/chronojump_manual_en.lyx~
+++ b/chronojump_manual_en.lyx~
@@ -9264,6 +9264,60 @@ Subsequently, in the analysis you can analyze the average error between
Creation and edition of the test types
\end_layout
+\begin_layout Standard
+You can edit or create as many tests as you want clicking on
+\begin_inset Graphics
+ filename /home/xpadulles/chronojump-docs/images/ForceSensor/Edit-Test-Button.png
+ scale 50
+
+\end_inset
+
+and
+\begin_inset Graphics
+ filename /home/xpadulles/chronojump-docs/images/ForceSensor/Create-Test-Button.png
+ scale 50
+
+\end_inset
+
+.
+\end_layout
+
+\begin_layout Standard
+\begin_inset Float figure
+wide false
+sideways false
+status open
+
+\begin_layout Plain Layout
+
+\end_layout
+
+\begin_layout Plain Layout
+\noindent
+\align center
+\begin_inset Graphics
+ filename images/ForceSensor/Create-Exercise-01_en.png
+ scale 50
+
+\end_inset
+
+
+\begin_inset Caption Standard
+
+\begin_layout Plain Layout
+Creation/Edition of a test type
+\end_layout
+
+\end_inset
+
+
+\end_layout
+
+\end_inset
+
+
+\end_layout
+
\begin_layout Subsection
Set edition
\end_layout
[
Date Prev][
Date Next] [
Thread Prev][
Thread Next]
[
Thread Index]
[
Date Index]
[
Author Index]