Bug #605259: Colorimeter name in profile description
Pascal de Bruijn
pmjdebruijn at pcode.nl
Tue Feb 16 21:56:10 UTC 2010
On Tue, Feb 16, 2010 at 10:43 PM, Richard Hughes <hughsient at gmail.com> wrote:
> On 16 February 2010 12:29, Pascal de Bruijn <pmjdebruijn at pcode.nl> wrote:
>> # color calibration device
>> ENV{COLOR_MEASUREMENT_DEVICE}=="*?", ENV{ACL_MANAGE}="1",
>> IMPORT{program}="/lib/udev/usb-db %p"
>
> Hmm, I don't think you need to include the full path this.
Well the other lines include full paths, it would seem good practice
consistency-wise.
>> Does this need to be in a particular place in 55-Argyll.rules? I
>> attached the full file.
>>
>> After making the above change, I rebooted my system, and ran the
>> udevadm monitor while plugging in the Huey. The results are attached.
>
> Good, so ID_VENDOR_FROM_DATABASE is being set, but it looks like
> ID_MODEL_FROM_DATABASE isn't -- do you have an up to date usb.ids? I
> assume this is a Huey:
>
> 0971 Gretag-Macbeth AG
> 2005 Huey
I updated the usb database, and guess what:
$ /lib/udev/usb-db /devices/pci0000:00/0000:00:1d.0/usb6/6-2
ID_VENDOR_FROM_DATABASE=Gretag-Macbeth AG
ID_MODEL_FROM_DATABASE=Huey
Regards,
Pascal de Bruijn