Bug #605259: Colorimeter name in profile description

Pascal de Bruijn pmjdebruijn at pcode.nl
Tue Feb 16 22:13:17 UTC 2010


On Tue, Feb 16, 2010 at 10:56 PM, Pascal de Bruijn <pmjdebruijn at pcode.nl> wrote:
> On Tue, Feb 16, 2010 at 10:43 PM, Richard Hughes <hughsient at gmail.com> wrote:
>> On 16 February 2010 12:29, Pascal de Bruijn <pmjdebruijn at pcode.nl> wrote:
>>> # color calibration device
>>> ENV{COLOR_MEASUREMENT_DEVICE}=="*?", ENV{ACL_MANAGE}="1",
>>> IMPORT{program}="/lib/udev/usb-db %p"
>>
>> Hmm, I don't think you need to include the full path this.
>
> Well the other lines include full paths, it would seem good practice
> consistency-wise.
>
>>> Does this need to be in a particular place in 55-Argyll.rules? I
>>> attached the full file.
>>>
>>> After making the above change, I rebooted my system, and ran the
>>> udevadm monitor while plugging in the Huey. The results are attached.
>>
>> Good, so ID_VENDOR_FROM_DATABASE is being set, but it looks like
>> ID_MODEL_FROM_DATABASE isn't -- do you have an up to date usb.ids? I
>> assume this is a Huey:
>>
>> 0971  Gretag-Macbeth AG
>>        2005  Huey
>
> I updated the usb database, and guess what:
>
> $ /lib/udev/usb-db /devices/pci0000:00/0000:00:1d.0/usb6/6-2
> ID_VENDOR_FROM_DATABASE=Gretag-Macbeth AG
> ID_MODEL_FROM_DATABASE=Huey

Ugh, I just calibrated my screen and it worked like a charm...

Please push the udev rule to Graeme.

Regards,
Pascal de Bruijn