[chronojump] Discover gui workin ok for raceAnalyzer



commit 27807a9d31a42dd9402667f4bd2c5e54eb0ba233
Author: Xavier de Blas <xaviblas gmail com>
Date:   Tue Jun 7 12:39:39 2022 +0200

    Discover gui workin ok for raceAnalyzer

 src/gui/app1/forceSensor.cs |  2 +-
 src/gui/app1/runEncoder.cs  | 15 +++------------
 2 files changed, 4 insertions(+), 13 deletions(-)
---
diff --git a/src/gui/app1/forceSensor.cs b/src/gui/app1/forceSensor.cs
index ce04274d3..92d5e2f97 100644
--- a/src/gui/app1/forceSensor.cs
+++ b/src/gui/app1/forceSensor.cs
@@ -267,7 +267,7 @@ public partial class ChronoJumpWindow
        {
                forceSensorOtherMessage = "Connecting ...";
 
-               portFS = new SerialPort (chronopicRegister.GetSelectedForMode (current_mode), 115200); 
//forceSensor
+               portFS = new SerialPort (chronopicRegister.GetSelectedForMode (current_mode), 115200);
                LogB.Information(" FS connect 4: opening port...");
 
                try {
diff --git a/src/gui/app1/runEncoder.cs b/src/gui/app1/runEncoder.cs
index f61274b17..1bbabb2c6 100644
--- a/src/gui/app1/runEncoder.cs
+++ b/src/gui/app1/runEncoder.cs
@@ -220,24 +220,16 @@ public partial class ChronoJumpWindow
        private bool runEncoderConnect()
        {
                LogB.Information(" RE connect 0 ");
-               if(chronopicRegister.ConnectedOfType(ChronopicRegisterPort.Types.ARDUINO_RUN_ENCODER) == null)
+               if (chronopicRegister.GetSelectedForMode (current_mode) == "")
                {
                        runEncoderPulseMessage = runEncoderNotConnectedString;
                        return false;
                }
 
                LogB.Information(" RE connect 1 ");
-               runEncoderPortName = 
chronopicRegister.ConnectedOfType(ChronopicRegisterPort.Types.ARDUINO_RUN_ENCODER).Port;
-               LogB.Information(" RE connect 2 ");
-               if(runEncoderPortName == null || runEncoderPortName == "")
-               {
-                       runEncoderPulseMessage = "Please, select port!";
-                       return false;
-               }
-               LogB.Information(" RE connect 3 ");
                runEncoderPulseMessage = "Connecting ...";
 
-               portRE = new SerialPort(runEncoderPortName, 115200); //runEncoder
+               portRE = new SerialPort (chronopicRegister.GetSelectedForMode (current_mode), 115200);
                LogB.Information(" RE connect 4: opening port...");
 
                try {
@@ -401,8 +393,7 @@ public partial class ChronoJumpWindow
                //if graphs are not updated with the line, use this that will fire ExposeEvent:
                //drawingarea_race_analyzer_capture_position_time.QueueDraw(); and the others
 
-
-               if(chronopicRegister.NumConnectedOfType(ChronopicRegisterPort.Types.ARDUINO_RUN_ENCODER) == 0)
+               if (chronopicRegister.GetSelectedForMode (current_mode) == "")
                {
                        event_execute_label_message.Text = runEncoderNotConnectedString;
                        runEncoderButtonsSensitive(true);


[Date Prev][Date Next]   [Thread Prev][Thread Next]   [Thread Index] [Date Index] [Author Index]