[gnome-settings-daemon] power: Fix UPS critical action being treated as a battery one



commit 085a88018737a6b69ec1c246629254dc9a52d2d6
Author: Bastien Nocera <hadess hadess net>
Date:   Wed Dec 19 17:51:52 2012 +0100

    power: Fix UPS critical action being treated as a battery one

 plugins/power/gsd-power-manager.c |    2 +-
 1 files changed, 1 insertions(+), 1 deletions(-)
---
diff --git a/plugins/power/gsd-power-manager.c b/plugins/power/gsd-power-manager.c
index cc2e8e1..fc4ec0b 100644
--- a/plugins/power/gsd-power-manager.c
+++ b/plugins/power/gsd-power-manager.c
@@ -1780,7 +1780,7 @@ engine_charge_action (GsdPowerManager *manager, UpDevice *device)
 
                 /* wait 20 seconds for user-panic */
                 timer_id = g_timeout_add_seconds (critical_action_delay,
-                                                  (GSourceFunc) manager_critical_action_do_cb,
+                                                  (GSourceFunc) manager_critical_ups_action_do_cb,
                                                   manager);
                 g_source_set_name_by_id (timer_id, "[GsdPowerManager] ups critical-action");
         }