Good evening Richard,<br>
<br>
and thanks for your time.<br>
<br>
I deleted the screen by using the Remove button in the Device panel.
I'm using the ATI driver (fglrx 2:8.780-0ubuntu2).<br>
<br>
I found the device-profiles.conf file, but it is empty, though I can
add a printer, a camera or a scanner via the GUI.<br>
<br>
I noticed that running "gcm-prefs -v" in a terminal gave an error
message related to my screen's edid: <br>
<i>TI:21:49:53.860823    FI:gcm-client.c    FN:gcm_client_xrandr_add,607<br>
 - failed to set for output: failed to parse edid</i><br>
<br>
Then I tried "gcm-dump-edid", which gave me the same error: <br>
<i>Impossible d'analyser le contenu EDID: failed to parse header<br>
</i><br>
When reading the bin file produced by this command, here is what I got:<br>
ȯ>yȯ>y/3x*TL�&PT��@�����@qO�:�q8-@X,E��8KQ<br>
      �SyncMaster<br>
  �H9XSB02945<br>
which obviously look weird.<br>
<br>
I suspected my screen edid to be corrupted, but "get-edid | parse-edid
" gives me a correct output:<br>
<i>vivien@Fixe:~$ sudo get-edid | parse-edid <br>
parse-edid: parse-edid version 2.0.0<br>
get-edid: get-edid version 2.0.0<br>
<br>
    Performing real mode VBE call<br>
    Interrupt 0x10 ax=0x4f00 bx=0x0 cx=0x0<br>
    Function supported<br>
    Call successful<br>
<br>
    VBE version 300<br>
    VBE string at 0xc01f0 "ATI ATOMBIOS"<br>
<br>
VBE/DDC service about to be called<br>
    Report DDC capabilities<br>
<br>
    Performing real mode VBE call<br>
    Interrupt 0x10 ax=0x4f15 bx=0x0 cx=0x0<br>
    Function supported<br>
    Call successful<br>
<br>
    Monitor and video card combination does not support DDC1 transfers<br>
    Monitor and video card combination supports DDC2 transfers<br>
    0 seconds per 128 byte EDID block transfer<br>
    Screen is not blanked during DDC transfer<br>
<br>
Reading next EDID block<br>
<br>
VBE/DDC service about to be called<br>
    Read EDID<br>
<br>
    Performing real mode VBE call<br>
    Interrupt 0x10 ax=0x4f15 bx=0x1 cx=0x0<br>
    Function supported<br>
    Call successful<br>
<br>
parse-edid: EDID checksum passed.<br>
<br>
    # EDID version 1 revision 3<br>
Section "Monitor"<br>
    # Block type: 2:0 3:fd<br>
    # Block type: 2:0 3:fc<br>
    Identifier "SyncMaster"<br>
    VendorName "SAM"<br>
    ModelName "SyncMaster"<br>
    # Block type: 2:0 3:fd<br>
    HorizSync 30-81<br>
    VertRefresh 56-75<br>
    # Max dot clock (video bandwidth) 170 MHz<br>
    # Block type: 2:0 3:fc<br>
    # Block type: 2:0 3:ff<br>
    # DPMS capabilities: Active off:yes  Suspend:no  Standby:no<br>
<br>
    Mode     "1920x1080"    # vfreq 60.000Hz, hfreq 67.500kHz<br>
        DotClock    148.500000<br>
        HTimings    1920 2008 2052 2200<br>
        VTimings    1080 1084 1089 1125<br>
        Flags    "+HSync" "+VSync"<br>
    EndMode<br>
    # Block type: 2:0 3:fd<br>
    # Block type: 2:0 3:fc<br>
    # Block type: 2:0 3:ff<br>
EndSection</i><br>
<br>
So I'm wondering whether my problem could be related to this edid issue.<br>
<br>
Will gcm correctly detect my screen if I manually specify it in the
device-profiles.conf file?<br>
<br>
Thanks for your help,<br>
<br>
Vivien<br>
<br>
On 17/10/2010 20:58, Richard Hughes wrote:
<blockquote
 cite="mid:AANLkTim63mnzg9MDD6Np+M88QYG9XSX1uzyMwaqCJgZ9@mail.gmail.com"
 type="cite">
  <pre wrap="">On 16 October 2010 11:05, Vivien Perez <a class="moz-txt-link-rfc2396E" href="mailto:vivien.perez@gmail.com"><vivien.perez@gmail.com></a> wrote:
  </pre>
  <blockquote type="cite">
    <pre wrap="">I've have recently accidentally deleted the line concerning my screen in GCM
device panel. I haven't found a way to get it back in, since when I try to
add a device, the pop-up menu only proposes to add scanners, printers or
cameras.
    </pre>
  </blockquote>
  <pre wrap="">
How did you delete the screen? It shouldn't let you delete "connected"
devices. By just starting the GCM control panel it should "re-add"
devices as required. I'm a bit confused why GCM seems to have got
confused. Are you using the binary NVIDIA driver per-chance?

  </pre>
  <blockquote type="cite">
    <pre wrap="">I have uninstalled and reinstalled GCM, but still no screen, and I didn't
find any option in GConf that could fix this.
    </pre>
  </blockquote>
  <pre wrap="">
The config is in device-profiles.conf in your home directory.

Richard
  </pre>